Invisiware Receiver Part # 516BC-R1252

FABRICATION OF NEW CABLE

  • Measure rail from outside of termination post to outside of termination post.
  • Subtract Take off from chart below depending on style of cable.
  • Cut cable to length.
  • Swage fittings onto cable.

516BC-R1252

**NOTE** Position the (threaded) stud onto the cable as shown.

SLIGHTLY LESS THAN CABLE DIAGRAM

Part (Side A) Part (Side B) Take Off
516BC-R1252 (3.030” LONG) 516BC-R1252 (3.030” LONG) 2 3/4
516BC-R1252 (3.030” LONG) w/ Beveled Washer 516BC-R1252 (3.030” LONG) 2 3/8
516BC-R1252 (3.030” LONG) w/ Beveled Washer 516BC-R1252 (3.030” LONG) w/ Beveled Washer 2

 

Single Side Take Off
Part Take off
516BC-R1252 (3.030” LONG) 1 3/8
516BC-R1252 (3.030” LONG) w/ Beveled Washer 1