Invisiware Receiver Part # 516BC-R1232
FABRICATION OF NEW CABLE
- Measure rail from outside of termination post to outside of termination post.
- Subtract Take off from chart below depending on style of cable.
- Cut cable to length.
- Swage fittings onto cable.
**NOTE** Position the (threaded) stud onto the cable as shown.
SLIGHTLY LESS THAN CABLE DIAGRAM
Part (Side A) | Part (Side B) | Take Off |
516BC-R1232 (2.03” LONG) | 516BC-R1232 (2.03” LONG) | 13/16 |
516BC-R1232 2.03” LONG) w/ Beveled Washer |
516BC-R1232 (2.03” LONG) | 7/16 |
516BC-R1232 (2.03” LONG) w/ Beveled Washer | 516BC-R1232 (2.03” LONG) w/ Beveled Washer |
1/16 |
Single Side Take Off | |
Part | Take off |
516BC-R1232 (2.03” LONG) | 3/8 |
516BC-R1232 (2.03” LONG) w/ Beveled Washer |
0 |