Invisiware Receiver Part # 316BC-R612
FABRICATION OF NEW CABLE
- Measure rail from outside of termination post to outside of termination post.
- Subtract Take off from chart below depending on style of cable.
- Cut cable to length.
- Swage fittings onto cable.
**NOTE** Position the (threaded) stud onto the cable as shown.
SLIGHTLY LESS THAN CABLE DIAGRAM
Part (Side A) | Part (Side B) | Take Off |
316BC-R612 (1.56” LONG) | 316BC-R612 (1.56” LONG) | .75 |
316BC-R612 (1.56” LONG) w/ Beveled Washer |
316BC-R612 (1.56” LONG) | 0.4375 |
316BC-R612 (1.56” LONG) w/ Beveled Washer | 316BC-R612 (1.56” LONG) w/ Beveled Washer | 0.125 |
Single Side Take Off | |
Part | Take off |
316BC-R612 (1.56” LONG) | .375 |
316BC-R612 (1.56” LONG) w/ Beveled Washer |
.0625 |