Invisiware Receiver Part # 18BC-R682

FABRICATION OF NEW CABLE

  • Measure rail from outside of termination post to outside of termination post.
  • Subtract Take off from chart below depending on style of cable.
  • Cut cable to length.
  • Swage fittings onto cable.

invisiware receiver 18BC-R682

**NOTE** Position the (threaded) stud onto the cable as shown.

SLIGHTLY LESS THAN CABLE DIAGRAM

Part (Side A)Part (Side B)Take Off
18BC-R682 (2.53” LONG)18BC-R682 (2.53” LONG)2-9/16
18BC-R682 (2.53” LONG) w/ Beveled Washer18BC-R682 (2.53” LONG)2-1/4
18BC-R682 (2.53” LONG) w/ Beveled Washer18BC-R682 (2.53” LONG) w/ Beveled Washer1-15/16

Single Side Take Off
PartTake off
18BC-R682 (2.53” LONG)1-1/4
18BC-R682 (2.53” LONG) w/ Beveled Washer15/16