Invisiware Receiver Part # 14BC-R852

FABRICATION OF NEW CABLE

  • Measure rail from outside of termination post to outside of termination post.
  • Subtract Take off from chart below depending on style of cable.
  • Cut cable to length.
  • Swage fittings onto cable.

14BC-R852

**NOTE** Position the (threaded) stud onto the cable as shown.

SLIGHTLY LESS THAN CABLE DIAGRAM

Part (Side A)Part (Side B)Take Off
14BC-R852 (3.03” LONG)14BC-R852 (3.03” LONG)2-7/8
14BC-R852 (3.03” LONG) w/ Beveled Washer
14BC-R852 (3.03” LONG)2-9/16
14BC-R852 (3.03” LONG) w/ Beveled Washer14BC-R852 (3.03” LONG) w/ Beveled Washer2-1/4

Single Side Take Off
PartTake off
14BC-R852 (3.03” LONG)1-7/16
14BC-R852 (3.03” LONG) w/ Beveled Washer1-1/8